Source code for nirfmxwcdma.chp_configuration

"""Provides methods to configure the Chp measurement."""

import functools

import nirfmxwcdma.attributes as attributes
import nirfmxwcdma.enums as enums
import nirfmxwcdma.errors as errors
import nirfmxwcdma.internal._helper as _helper


def _raise_if_disposed(f):
    """From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""

    @functools.wraps(f)
    def aux(*xs, **kws):
        meas_obj = xs[0]  # parameter 0 is 'self' which is the measurement object
        if meas_obj._signal_obj.is_disposed:
            raise Exception("Cannot access a disposed Wcdma signal configuration")
        return f(*xs, **kws)

    return aux


[docs] class ChpConfiguration(object): """Provides methods to configure the Chp measurement.""" def __init__(self, signal_obj): """Provides methods to configure the Chp measurement.""" self._signal_obj = signal_obj self._session_function_lock = signal_obj._session_function_lock self._interpreter = signal_obj._interpreter
[docs] @_raise_if_disposed def get_measurement_enabled(self, selector_string): r"""Gets whether to enable the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_measurement_enabled(self, selector_string, value): r"""Sets whether to enable the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_carrier_integration_bandwidth(self, selector_string): r"""Gets the frequency range, over which the measurement integrates the power. This value is expressed in Hz. Use "carrier<*n*>" as the selector string to read this attribute. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the frequency range, over which the measurement integrates the power. This value is expressed in Hz. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_CARRIER_INTEGRATION_BANDWIDTH.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_rbw_filter_auto_bandwidth(self, selector_string): r"""Gets whether the measurement computes the RBW. This attribute is valid only if you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_TYPE` attribute to **Gaussian** or **Flat**. If you set the CHP RBW Filter Type attribute to **FFT Based**, the measurement calculates the RBW regardless of what you set in this attribute. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+-------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================================+ | False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. | +--------------+-------------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+-------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpRbwAutoBandwidth): Specifies whether the measurement computes the RBW. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value ) attr_val = enums.ChpRbwAutoBandwidth(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_auto_bandwidth(self, selector_string, value): r"""Sets whether the measurement computes the RBW. This attribute is valid only if you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_TYPE` attribute to **Gaussian** or **Flat**. If you set the CHP RBW Filter Type attribute to **FFT Based**, the measurement calculates the RBW regardless of what you set in this attribute. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+-------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================================+ | False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. | +--------------+-------------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+-------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpRbwAutoBandwidth, int): Specifies whether the measurement computes the RBW. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpRbwAutoBandwidth else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_rbw_filter_bandwidth(self, selector_string): r"""Gets the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This attribute is valid only if you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_TYPE` attribute to **Gaussian** or **Flat**. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 50 kHz. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Specifies the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_bandwidth(self, selector_string, value): r"""Sets the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This attribute is valid only if you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_TYPE` attribute to **Gaussian** or **Flat**. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 50 kHz. Args: selector_string (string): Pass an empty string. value (float): Specifies the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_rbw_filter_type(self, selector_string): r"""Gets the shape of the digital RBW filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **FFT Based**. +---------------+----------------------------------------------------+ | Name (Value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is applied. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpRbwFilterType): Specifies the shape of the digital RBW filter. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value ) attr_val = enums.ChpRbwFilterType(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_type(self, selector_string, value): r"""Sets the shape of the digital RBW filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **FFT Based**. +---------------+----------------------------------------------------+ | Name (Value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is applied. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpRbwFilterType, int): Specifies the shape of the digital RBW filter. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpRbwFilterType else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_sweep_time_auto(self, selector_string): r"""Gets whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+---------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=======================================================================================+ | False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. | +--------------+---------------------------------------------------------------------------------------+ | True (1) | The measurement uses a sweep time value of one slot duration. | +--------------+---------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpSweepTimeAuto): Specifies whether the measurement computes the sweep time. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value ) attr_val = enums.ChpSweepTimeAuto(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_sweep_time_auto(self, selector_string, value): r"""Sets whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+---------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=======================================================================================+ | False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. | +--------------+---------------------------------------------------------------------------------------+ | True (1) | The measurement uses a sweep time value of one slot duration. | +--------------+---------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpSweepTimeAuto, int): Specifies whether the measurement computes the sweep time. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpSweepTimeAuto else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_sweep_time_interval(self, selector_string): r"""Gets the sweep time when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 666.66666700000007 microseconds. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Specifies the sweep time when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_sweep_time_interval(self, selector_string, value): r"""Sets the sweep time when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 666.66666700000007 microseconds. Args: selector_string (string): Pass an empty string. value (float): Specifies the sweep time when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_enabled(self, selector_string): r"""Gets whether to enable averaging for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The CHP measurement uses the value of the CHP Averaging Count attribute as the number of acquisitions over which the | | | CHP measurement is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpAveragingEnabled): Specifies whether to enable averaging for the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value ) attr_val = enums.ChpAveragingEnabled(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_enabled(self, selector_string, value): r"""Sets whether to enable averaging for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The CHP measurement uses the value of the CHP Averaging Count attribute as the number of acquisitions over which the | | | CHP measurement is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpAveragingEnabled, int): Specifies whether to enable averaging for the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpAveragingEnabled else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_count(self, selector_string): r"""Gets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_count(self, selector_string, value): r"""Sets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. value (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxwcdma.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_type(self, selector_string): r"""Gets the averaging type for averaging the spectrum of multiple acquisitions. The averaged spectrum is used for CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. the default value is **RMS**. +--------------+-------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=============================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged in a logarithmic scale. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Min (4) | The lowest power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpAveragingType): Specifies the averaging type for averaging the spectrum of multiple acquisitions. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value ) attr_val = enums.ChpAveragingType(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_type(self, selector_string, value): r"""Sets the averaging type for averaging the spectrum of multiple acquisitions. The averaged spectrum is used for CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. the default value is **RMS**. +--------------+-------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=============================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged in a logarithmic scale. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Min (4) | The lowest power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpAveragingType, int): Specifies the averaging type for averaging the spectrum of multiple acquisitions. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpAveragingType else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_amplitude_correction_type(self, selector_string): r"""Gets whether the amplitude of the frequency bins, used in measurements, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the `RFmxInstr Configure External Attenuation <rfmxinstrvi.chm/RFmxInstr_Configure_External_Attenuation_Table.html>`_ method to configure the external attenuation table. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **RF Center Frequency**. +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +============================+==========================================================================================================================+ | RF Center Frequency (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the | | | RF center frequency. | +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Spectrum Frequency Bin (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that | | | frequency. | +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpAmplitudeCorrectionType): Specifies whether the amplitude of the frequency bins, used in measurements, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the `RFmxInstr Configure External Attenuation <rfmxinstrvi.chm/RFmxInstr_Configure_External_Attenuation_Table.html>`_ method to configure the external attenuation table. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AMPLITUDE_CORRECTION_TYPE.value ) attr_val = enums.ChpAmplitudeCorrectionType(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_amplitude_correction_type(self, selector_string, value): r"""Sets whether the amplitude of the frequency bins, used in measurements, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the `RFmxInstr Configure External Attenuation <rfmxinstrvi.chm/RFmxInstr_Configure_External_Attenuation_Table.html>`_ method to configure the external attenuation table. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **RF Center Frequency**. +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +============================+==========================================================================================================================+ | RF Center Frequency (0) | All the frequency bins in the spectrum are compensated with a single external attenuation value that corresponds to the | | | RF center frequency. | +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Spectrum Frequency Bin (1) | An individual frequency bin in the spectrum is compensated with the external attenuation value corresponding to that | | | frequency. | +----------------------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpAmplitudeCorrectionType, int): Specifies whether the amplitude of the frequency bins, used in measurements, is corrected for external attenuation at the RF center frequency, or at the individual frequency bins. Use the `RFmxInstr Configure External Attenuation <rfmxinstrvi.chm/RFmxInstr_Configure_External_Attenuation_Table.html>`_ method to configure the external attenuation table. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpAmplitudeCorrectionType else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AMPLITUDE_CORRECTION_TYPE.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_all_traces_enabled(self, selector_string): r"""Gets whether to enable the traces to be stored and retrieved after performing the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_all_traces_enabled(self, selector_string, value): r"""Sets whether to enable the traces to be stored and retrieved after performing the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_number_of_analysis_threads(self, selector_string): r"""Gets the maximum number of threads used for parallelism for the CHP measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the maximum number of threads used for parallelism for the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_number_of_analysis_threads(self, selector_string, value): r"""Sets the maximum number of threads used for parallelism for the CHP measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. value (int): Specifies the maximum number of threads used for parallelism for the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_averaging( self, selector_string, averaging_enabled, averaging_count, averaging_type ): r"""Configures averaging for the CHP measurement. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. averaging_enabled (enums.ChpAveragingEnabled, int): This parameter specifies whether to enable averaging of the spectrum for the measurement. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The measurement uses the **Averaging Count** parameter to calculate the number of acquisitions over which the spectrum | | | is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ averaging_count (int): This parameter specifies the number of acquisitions used for averaging when you set the **Averaging Enabled** parameter to **True**. The default value is 10. averaging_type (enums.ChpAveragingType, int): This parameter specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the measurement. The default value is **RMS**. +--------------+------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. | +--------------+------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged in a logarithmic scale. | +--------------+------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one record to the next. | +--------------+------------------------------------------------------------------------------------------------+ | Min (4) | The least power in the spectrum at each frequency bin is retained from one record to the next. | +--------------+------------------------------------------------------------------------------------------------+ Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") averaging_enabled = ( averaging_enabled.value if type(averaging_enabled) is enums.ChpAveragingEnabled else averaging_enabled ) averaging_type = ( averaging_type.value if type(averaging_type) is enums.ChpAveragingType else averaging_type ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_averaging( updated_selector_string, averaging_enabled, averaging_count, averaging_type ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_rbw_filter(self, selector_string, rbw_auto, rbw, rbw_filter_type): r"""Configures the RBW filter. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. rbw_auto (enums.ChpRbwAutoBandwidth, int): This parameter specifies whether the measurement computes the RBW. The default value is **True**. This parameter is valid only if you set the **RBW Filter Type** parameter to **Gaussian** or **Flat**. If you set the **RBW Filter Type** parameter to **FFT Based**, the measurement calculates the RBW regardless of the value of this parameter. +--------------+-------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================================+ | False (0) | The measurement uses the RBW that you specify in the **RBW** parameter. | +--------------+-------------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+-------------------------------------------------------------------------+ rbw (float): This parameter specifies the bandwidth of the RBW filter used to sweep the acquired signal when you set the **RBW Auto** parameter to **False**. This parameter is valid only if you set the **RBW Filter Type** parameter to **Gaussian** or **Flat**. This value is expressed in Hz. The default value is 50 kHz. rbw_filter_type (enums.ChpRbwFilterType, int): This parameter specifies the shape of the digital RBW filter. The default value is **Gaussian**. +---------------+----------------------------------------------------+ | Name (Value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is performed. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") rbw_auto = rbw_auto.value if type(rbw_auto) is enums.ChpRbwAutoBandwidth else rbw_auto rbw_filter_type = ( rbw_filter_type.value if type(rbw_filter_type) is enums.ChpRbwFilterType else rbw_filter_type ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_rbw_filter( updated_selector_string, rbw_auto, rbw, rbw_filter_type ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_sweep_time(self, selector_string, sweep_time_auto, sweep_time_interval): r"""Configures the sweep time interval. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. sweep_time_auto (enums.ChpSweepTimeAuto, int): This parameter specifies whether the measurement computes the sweep time. The default value is **True**. +--------------+------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+================================================================================================+ | False (0) | The measurement uses the sweep time that you specify in the **Sweep Time Interval** parameter. | +--------------+------------------------------------------------------------------------------------------------+ | True (1) | The measurement uses a sweep time value of one slot duration. | +--------------+------------------------------------------------------------------------------------------------+ sweep_time_interval (float): This parameter specifies the sweep time when you set the **Sweep Time Auto** parameter to **False**. This value is expressed in seconds. The default value is 666.66666700000007 microseconds. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") sweep_time_auto = ( sweep_time_auto.value if type(sweep_time_auto) is enums.ChpSweepTimeAuto else sweep_time_auto ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_sweep_time( updated_selector_string, sweep_time_auto, sweep_time_interval ) finally: self._session_function_lock.exit_read_lock() return error_code