SlotPowerConfiguration

Provides methods to configure the SlotPower measurement.

class nirfmxwcdma.slotpower_configuration.SlotPowerConfiguration(signal_obj)[source]

Bases: object

Provides methods to configure the SlotPower measurement.

configure_synchronization_mode_and_interval(selector_string, synchronization_mode, measurement_offset, measurement_length)[source]

Configures the synchronization mode, measurement offset, and measurement length.

Parameters:
  • selector_string (string) – Pass an empty string. The signal name that is passed when creating the signal configuration is used.

  • synchronization_mode (enums.SlotPowerSynchronizationMode, int) –

    This parameter specifies whether the measurement is performed from the frame or slot boundary.

    The default value is Slot.

    Name (Value)

    Description

    Frame (0)

    The frame boundary is detected, and the measurement is performed over the number of slots expressed by the Measurement Length attribute starting at Measurement Offset slots from the frame boundary.

    Slot (1)

    The slot boundary is detected and the measurement is performed over the number of slots expressed by Measurement Length parameter, starting at Measurement Offset slots from the slot boundary.

  • measurement_offset (int) –

    This parameter specifies the measurement offset to skip from the synchronization boundary. This value is expressed in slots. The synchronization boundary is specified by the Synchronization Mode parameter.

    The default value is 0. The valid values are any value greater than or equal to 0.

  • measurement_length (int) –

    This parameter specifies the duration of the SlotPower measurement. This value is expressed in slots.

    The default value is 15. The valid values are any value greater than or equal to 1.

Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

get_measurement_enabled(selector_string)[source]

Gets whether to enable the SlotPower measurement.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is FALSE.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (bool):

Specifies whether to enable the SlotPower measurement.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

get_measurement_length(selector_string)[source]

Gets the duration of the SlotPower measurement. This value is expressed in slots.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is 15. The valid values are any value greater than or equal to 1.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (int):

Specifies the duration of the SlotPower measurement. This value is expressed in slots.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

get_measurement_offset(selector_string)[source]

Gets the measurement offset to skip from the synchronization boundary. This value is expressed in slots. The synchronization boundary is specified by the SLOTPOWER_SYNCHRONIZATION_MODE attribute.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is 0. The valid values are any value greater than or equal to 0.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (int):

Specifies the measurement offset to skip from the synchronization boundary. This value is expressed in slots. The synchronization boundary is specified by the SLOTPOWER_SYNCHRONIZATION_MODE attribute.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

get_rrc_filter_enabled(selector_string)[source]

Gets whether to enable the RRC filter.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

Name (Value)

Description

False (0)

Disables the RRC filter in the measurement.

True (1)

Enables the RRC filter in the measurement.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (enums.SlotPowerRrcFilterEnabled):

Specifies whether to enable the RRC filter.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

get_spectrum_inverted(selector_string)[source]

Gets whether the spectrum of the signal is inverted.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

Name (Value)

Description

False (0)

The spectrum is not inverted.

True (1)

The spectrum is inverted.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (enums.SlotPowerSpectrumInverted):

Specifies whether the spectrum of the signal is inverted.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

get_synchronization_mode(selector_string)[source]

Gets whether the measurement is performed from the frame or slot boundary.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is Slot.

Name (Value)

Description

Frame (0)

The frame boundary is detected, and the measurement is performed over the number of slots expressed by the SlotPower Measurement Length attribute starting at SlotPower Meas offset slots from the frame boundary.

Slot (1)

The slot boundary is detected, and the measurement is performed over the number of slots expressed by the SlotPower Measurement Length attribute starting at SlotPower Measurement Offset slots from the slot boundary.

Parameters:

selector_string (string) – Pass an empty string.

Returns:

attr_val (enums.SlotPowerSynchronizationMode):

Specifies whether the measurement is performed from the frame or slot boundary.

error_code (int):

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

Tuple (attr_val, error_code)

set_measurement_enabled(selector_string, value)[source]

Sets whether to enable the SlotPower measurement.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is FALSE.

Parameters:
  • selector_string (string) – Pass an empty string.

  • value (bool) – Specifies whether to enable the SlotPower measurement.

Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

set_measurement_length(selector_string, value)[source]

Sets the duration of the SlotPower measurement. This value is expressed in slots.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is 15. The valid values are any value greater than or equal to 1.

Parameters:
  • selector_string (string) – Pass an empty string.

  • value (int) – Specifies the duration of the SlotPower measurement. This value is expressed in slots.

Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

set_measurement_offset(selector_string, value)[source]

Sets the measurement offset to skip from the synchronization boundary. This value is expressed in slots. The synchronization boundary is specified by the SLOTPOWER_SYNCHRONIZATION_MODE attribute.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is 0. The valid values are any value greater than or equal to 0.

Parameters:
  • selector_string (string) – Pass an empty string.

  • value (int) – Specifies the measurement offset to skip from the synchronization boundary. This value is expressed in slots. The synchronization boundary is specified by the SLOTPOWER_SYNCHRONIZATION_MODE attribute.

Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

set_rrc_filter_enabled(selector_string, value)[source]

Sets whether to enable the RRC filter.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

Name (Value)

Description

False (0)

Disables the RRC filter in the measurement.

True (1)

Enables the RRC filter in the measurement.

Parameters:
Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

set_spectrum_inverted(selector_string, value)[source]

Sets whether the spectrum of the signal is inverted.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is False.

Name (Value)

Description

False (0)

The spectrum is not inverted.

True (1)

The spectrum is inverted.

Parameters:
Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int

set_synchronization_mode(selector_string, value)[source]

Sets whether the measurement is performed from the frame or slot boundary.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is Slot.

Name (Value)

Description

Frame (0)

The frame boundary is detected, and the measurement is performed over the number of slots expressed by the SlotPower Measurement Length attribute starting at SlotPower Meas offset slots from the frame boundary.

Slot (1)

The slot boundary is detected, and the measurement is performed over the number of slots expressed by the SlotPower Measurement Length attribute starting at SlotPower Measurement Offset slots from the slot boundary.

Parameters:
Returns:

Returns the status code of this method. The status code either indicates success or describes a warning condition.

Return type:

int